01What this covers
On an MIDC industrial plot, "how much can I build?" is answered by the Comprehensive Development Control and Promotion Regulations for MIDC (CDCPR). The Urban Development Department sanctioned it by notification No. TPB-4322/314/CR-25/2022/UD-11 dated 5 July 2023, and it came into force on publication in the Gazette on 13 July 2023. From then, the regulations previously in operation "shall cease to operate" (Reg. 1.2, p. 17), so the 2009 MIDC DCR is not used here.
A corrigendum dated 21 May 2025 changed some provisions. Where it touches a figure below, this guide gives the amended figure and says so. Page numbers are Gazette pages of the 2023 notification; "Corr." pages are pages of the 2025 corrigendum.
This guide covers the building envelope only. For the approval sequence, see building a factory on an MIDC plot.
02Marginal distances (setbacks) and height: Table 5A
The regulation says: Table 5A sets the minimum marginal distances "for industrial building permissible in industrial or other zones" (Reg. 5.1, p. 84). It is reproduced as printed, with row 4 as rectified in 2025 (entry 27, Corr. pp. 30–31). Figures are in metres.
| Sr. | Plot size | Front | Side | Rear | Maximum height |
|---|---|---|---|---|---|
| 1 | Stall sites up to 25 sqm | 0.75 | 0.75 | 0.75 | 3.5 |
| 2 | Above 25 sqm to 60 sqm | 1.00 | 0.75 | 0.75 | 7.00 |
| 3 | Above 60 sqm and up to 100 sqm | 1.50 | 1.00 | 1.00 | 10.00 |
| 4 | Above 100 sqm and up to 300 sqm | 2.50 | 1.50 | 1.50 | 15 |
| 5 | Above 300 sqm and up to 500 sqm | 3.00 | 3.00 | 3.00 | Subject to marginal distance, as per Reg. 5.4 |
| 6 | Above 500 sqm and up to 1200 sqm, not being a special building | 4.00 | 3.00 | 3.00 | -- do -- |
| 7 | Above 1200 sqm, not being a special building | 5.00 | 4.00 | 4.00 | -- do -- |
| 8 | Any building in the above categories, being a special building | 6.00 | 6.00 | 6.00 | -- do -- |
What changed in 2025: row 4's maximum height was 10.00 in the 2023 text (p. 84) and is now 15. A new note says rows 1 to 4 "will be applicable to all types of land uses for plot sizes up to 300 sq.m." (Corr. p. 31).
Notes to the table (pp. 84–85) include:
- On National Highways, State Highways and Major District Roads, the building line follows the Ribbon Development Rules or the table, "whichever is more".
- "Maximum floor height shall be generally 6.0 m for industrial buildings. However, greater heights maybe permitted as per the requirement, without accounting for additional FSI."
- Buildings may be connected for a manufacturing process (for example by a conveyor belt), with light and ventilation complied with "instead of insisting for distance between two buildings".
Practical tip: row 8 depends on whether your building is a "special building". Under Reg. 1.3(111)(xiv) (p. 30), that includes industrial and storage buildings with more than 500 sqm on any one or more floors. Most factory and warehouse designs on larger plots should be checked against the 6 m row first.
03Taller buildings and distance between blocks
The regulation says (Reg. 5.4, pp. 91–92):
- A special building needs a front margin of at least 6.00 m "irrespective of its height".
- Above the table height, the side and rear distance is at least H/5 (H = height above ground level). Parking floors up to 6 m and one service floor are excluded from H.
- For special buildings the minimum is 6 m; 9 m at 45 m and below 70 m; 12 m at 70 m and above. The distance is capped at 12 m from the boundary and 16 m between two buildings.
- Where a side has dead walls (no light and ventilation drawn from it), the distance may be reduced to 3.0 m for non-special and 6 m for special buildings, subject to the fire-access rule in Reg. 2.2.8(i).
- Two buildings on one plot must be separated by the side or rear distance required for the taller one (Reg. 5.4.1, p. 92).
- A building on two or more streets keeps the setback from each street (Reg. 5.4.2, p. 92).
04Height limits
The regulation says (Reg. 5.9, pp. 96–97):
- Special buildings may go to any height, subject to MIDC's Chief Fire Officer, "depending upon the fire fighting capacity available in the vicinity".
- Height up to 24 m is allowed on roads below 12 m (subject to the minimum road width for special buildings). Above 24 m, the road must be at least 12 m.
- Near aerodromes, Civil Aviation parameters or an Airport Authority NOC apply.
- Hazardous godowns for inflammable materials and explosives must be single-storeyed.
- Roof tanks, lift rooms, chimneys, non-inhabited processing towers and solar panels are not counted in height (Reg. 5.10, p. 97).
05FSI: Table 5D
The regulation says: FSI for all building types, industrial included, depends on road width (Reg. 5.5, pp. 92–93). The 2025 corrigendum only rewords the opening sentence (entry 30, Corr. p. 32).
| Road width | Basic FSI | FSI on payment of premium | Maximum building potential on plot including in-situ FSI |
|---|---|---|---|
| Below 9 m | 1.00 | -- | 1.00 |
| 9 m and above but below 12 m | 1.00 | 1.00 | 2.00 |
| 12 m and above but below 15 m | 1.00 | 1.25 | 2.25 |
| 15 m and above but below 24 m | 1.00 | 1.50 | 2.50 |
| 24 m and above but below 30 m | 1.00 | 1.75 | 2.75 |
| 30 m and above | 1.00 | 2.00 | 3.00 |
Notes to Table 5D (pp. 93–94):
- Ancillary area FSI is allowed on top of the table, on premium at 10% of the land rate (MIDC land rates, or the Annual Statement of Rates if MIDC rates are not available). For industrial use it is "upto 80%" of the proposed FSI.
- Premium FSI costs "25% for industrial use, 50% for commercial use and 35% for other uses" of the land rate.
- Table limits may be exceeded only as provided in Chapters 6 and 12.
- On a dead-end access road, the table's potential applies only if that road is not longer than 100 m.
Built-up area is measured on the outer periphery of each floor, the "P-line" (Reg. 5.6, p. 94). Effluent treatment plant structures, sub-station and generator areas, meter rooms, chimneys and non-inhabited processing towers are excluded from FSI (Reg. 5.8, p. 96). A plot in an approved layout counts as the net plot area (Reg. 3.7(iv), p. 73).
06Ground coverage
The regulation says: we did not find a ground-coverage percentage for industrial buildings in the CDCPR's Chapter 5 or in the 2025 corrigendum. The only "coverage" table is for lofts (Table 8B, p. 121: an industrial loft may cover 33% of the room below).
Practical tip: in our reading, the footprint on an MIDC plot is set by the marginal distances, the clear distance kept around the building, any recreational open space, and FSI. Read your lease deed too, as it may add conditions.
07Open space, buffers and mixed uses
| Item | What CDCPR 2023 says | Regulation / page |
|---|---|---|
| Recreational open space | Plots of 1.00 ha and above on MIDC land earmark 10% at building / development permission. In MIDC layouts developed before August 2009, plots above 1 ha and up to 4 ha are exempt | Reg. 3.4.1, p. 67 |
| Buffer to residential | Minimum 23 m from the industrial building / use to residential or habitable use (30 m for chemical industries); not deducted for FSI; not needed if the land is used entirely for non-polluting industries, IT / ITES or like purposes | Reg. 4.2.1(ii), p. 76 |
| Offices and display | Office up to 10% and commercial display up to 5% of the total built-up area of the industrial building / use | Reg. 4.2.1(iii), p. 76 |
| Staff quarters | Up to 10% of plot area on non-chemical plots above 0.4 ha; not allowed below 0.4 ha or on chemical plots | Reg. 4.2.1(iii), p. 76 |
| Minimum plot area | High hazard 4000 sqm; moderate hazard 2000 sqm; light hazard / small scale / other industries 200 sqm, width 10 m | Reg. 3.6, Table 3I, p. 71 |
08Parking and loading / unloading
The regulation says:
| Item | What CDCPR 2023 says | Regulation / page |
|---|---|---|
| Industrial parking | Per 200 sqm built-up area or fraction: 1 car, 2 scooters. On plots of 1 ha and above, minimum parking space is 10% of plot area | Table 7C, Sr. 9, p. 116 |
| Storage / warehouse | "Storage (any type) for office - Warehouse Facility": per 300 sqm built-up area or fraction, 1 car, 2 scooters | Table 7C, Sr. 10, p. 116 |
| Area factor | 1.00 for "Mumbai & Pune Metropolitan Region"; 0.8 for Nagpur, Nashik, Aurangabad Metropolitan Region and DMIC nodes; 0.6 for other areas | Reg. 7.2.2, Table 7D, p. 118 |
| Space sizes | Car 2.50 m x 5.00 m; transport vehicle 3.75 m x 10.00 m; trailer truck 5.00 m x 20.00 m | Table 7A, p. 110 |
| Loading bays | Industrial and storage building: 3.75 m x 10.00 m; the "Required spaces" column reads "As above." Separate bays may not be needed where loading is shown on the plan at different locations | Table 7B, p. 111 |
| Where parking can go | In addition to marginal distances; surface parking allowed if a clear distance (3 m; 6 m for special buildings below 45 m) around the building stays free of parking and loading. The 2025 text drops mechanical / puzzle parking and sheet roofing from this clause | Reg. 7.1.1(viii)(d), p. 111; Corr. entry 34, p. 35 |
Practical tip: Table 7D names regions, not MIDC areas. Ask MIDC which factor it applies to your area before relying on 1.00. Truck turning and docking usually decide yard size more than the minimum bay count.
09How to work out what you can build
- 1Confirm plot data. Take plot area from the lease deed or MIDC demarcation plan, and the width of the fronting road as defined in Reg. 1.3(128) (p. 33).
- 2Read the FSI row. Find your road width in Table 5D and note basic FSI, premium FSI and maximum potential.
- 3Budget for premiums. Premium FSI is 25% of the land rate for industrial use; ancillary FSI (up to 80%) is 10%.
- 4Decide special-building status. If any floor exceeds 500 sqm, use the 6 m row and the special-building rules in Reg. 5.4.
- 5Mark setbacks. Apply Table 5A, then H/5 on sides and rear above the table height.
- 6Deduct open space and buffers. Set aside 10% open space on plots of 1 ha and above; check the 23 m or 30 m buffer next to residential use.
- 7Count parking and bays. Apply Table 7C, the Table 7D factor and Table 7B; keep the clear distance free.
- 8Check height. Confirm 12 m road width above 24 m, aerodrome limits and the CFO's view.
- 9Cross-check the lease. On land leased by the Government or its authorities, using more FSI than the lease deed mentions needs a no objection certificate (Reg. 2.2.3(viii), p. 43).
- 10Have your architect confirm the scheme against the CDCPR and with MIDC before you commit to a price or design. Ask MIDC also whether any order after 21 May 2025 changes these figures.
For an integrated logistics park or logistics park, the CDCPR has separate FSI and road-width rules in Reg. 12.3. See warehouse and logistics park rules.