01What this covers
Outside MIDC, the building rules for most land in Maharashtra are the Unified Development Control and Promotion Regulations (UDCPR), sanctioned on 02/12/2020. This guide covers only the provisions for industrial buildings and industrial uses that could be read with certainty in the official consolidated copy "Updated as on 30th January, 2025". Regulation and page numbers are as printed in that copy.
It does not cover fire safety, environmental clearance, TDR in detail, or permissions under other laws. For who grants permission and what happens without it, see industrial land outside MIDC: MRTP permission.
02Where UDCPR does not apply, including MIDC
The regulation says (Reg. 1.1(i), p. 1) that UDCPR applies to building activities and development works within all planning authorities and Regional Plan areas except the Municipal Corporation of Greater Mumbai and authorities within its limits, MIDC, NAINA, Jawaharlal Nehru Port Trust, hill station municipal councils, the Chikhaldara notified area, eco-sensitive or eco-fragile regions notified by MoEF & CC, and Lonavala Municipal Council. The title page (p. III) carries the same exclusion.
So a plot in an MIDC industrial area is not governed by UDCPR. See FSI and setbacks on MIDC plots for that.
Practical tip: if your land is in the Pune Metropolitan Region outside a municipal corporation, read which building rules apply in the PMRDA area first. UDCPR was applied there by a State directive dated 15.07.2026.
03Step one: the zone of the land
UDCPR treats an industrial building differently depending on the zone in the Development Plan or Regional Plan.
Industrial Zone (Reg. 4.8, pp. 65 to 66)
The regulation says:
- Any industry may be permitted (Reg. 4.8(ii)).
- A buffer open space or setback of not less than 23.0 m is required from the boundary of the industrial building or use to a residential or habitable zone or use. It may include marginal distance and road width, and is kept in the industrial-zone land. Its area is not deducted for FSI. It is not necessary if the land is used entirely for non-polluting industries, IT/ITES or like purposes.
- Industrial godowns and godowns are permissible.
- Accessory uses (banks, canteens, welfare centre, quarters for watchmen, caretakers or essential staff) may be permitted up to 25% of the total proposed built-up area of the industrial use (Reg. 4.8(iii)).
- Other permitted uses include storage buildings, industrial training institutes, IT/ITES, bio-technology units, EV charging and fuel stations, and hospitals (Reg. 4.8(iv)). Transport hub and logistic park, including warehousing, cold storage and container freight stations, is also listed (Reg. 4.8(v)).
Agricultural Zone (Reg. 4.11(xviii), p. 72; notes, p. 75)
The regulation says that any industry may be permitted in the Agricultural Zone, with:
- FSI of 0.20 without payment of premium;
- further FSI up to 1.00 on payment of premium at 20% of the land rate in the Annual Statement of Rates (without considering the guidelines therein);
- the same 23.0 m buffer from residential or habitable zone or use, kept in the same land, with the same non-polluting exception;
- industrial layout or sub-division permitted subject to Industrial Zone regulations, each plot entitled to 0.20 FSI and further FSI on premium; and
- industrial godowns and godowns permissible.
The notes to Reg. 4.11 (p. 75) add that the minimum road width for uses in this zone is 6.0 m for a non-special building, unless otherwise specified, and as per Reg. 3.3.9 for a special building. Height is as per Reg. 6.10, subject to FSI.
Practical tip: the gap between 0.20 FSI and 1.00 FSI is paid for. Price the premium into the land cost before you agree a rate for agricultural-zone land.
04Minimum plot size
The regulation says (Table No. 3D, Reg. 3.7, p. 53) that a plot for industrial use (other than service industries) must be at least 300 sq. m, with a minimum width of 10 m, as detached development.
05FSI and marginal distances in the Industrial Zone
The regulation says (Reg. 6.4, Table No. 6-H, p. 119) that minimum plot area, margins, basic FSI and premium FSI for industrial buildings in the industrial zone are as follows.
| Sr. | Min. road width | Plot size (sq. m) | Basic FSI | FSI on premium | Min. front margin | Min. side and rear margins | Regulation, page |
|---|---|---|---|---|---|---|---|
| 1 | 9 m | Up to 300 | 1.00 | 0.40 | 3.00 m | 2.25 m | Reg. 6.4, Table 6-H, p. 119 |
| 2 | 9 m | Above 300 and up to 500 | 1.00 | 0.40 | 3.00 m | 3.00 m | Reg. 6.4, Table 6-H, p. 119 |
| 3 | 9 m | Above 500 and up to 1000, not being special building | 1.00 | 0.40 | 4.5 m | 3.00 m | Reg. 6.4, Table 6-H, p. 119 |
| 4 | 12 m | Above 1000, not being special building | 1.00 | 0.40 | 4.5 m | 4.50 m | Reg. 6.4, Table 6-H, p. 119 |
| 5 | 12 m | Above 500, being special building | 1.00 | 0.40 | 6.0 m | 6.00 m | Reg. 6.4, Table 6-H, p. 119 |
The notes to Table 6-H (p. 119) say:
- Ancillary area FSI up to 80% of the proposed FSI (basic plus premium, excluding Reg. 6.8 items) is allowed on payment of premium under Reg. 6.1.1. The notes under Table 6-G relevant to industrial use also apply.
- In Regional Plan areas, for plots fronting a National Highway, State Highway or Major District Road, the building line or control line is as per the Ribbon Development Rules or the table, whichever is more.
- Maximum floor height is 4.5 m for industrial buildings, but greater heights may be permitted as per requirement.
- A 23.0 m buffer zone is kept from a residential or incompatible zone wherever necessary. Roads and marginal distances may count as part of it, and its area within the plot counts in gross area for FSI. It is not necessary for land used entirely for non-polluting industries or IT/ITES.
06When an industrial building is a "special building"
The table's last row turns on this. The regulation says (Reg. 1.3(93)(xiv), p. 11) that a special building includes:
- any multi-storeyed building more than 24 m in height from ground level; or
- a building for industrial, storage or hazardous (among other) occupancies with built-up area of 500 sq. m or more on any floor, irrespective of height.
Practical tip: most factory and warehouse sheds will have 500 sq. m or more on the ground floor, so row 5 of Table 6-H (12 m road, 6.0 m margins) is often the one to test first.
07Height
The regulation says (Reg. 6.10.1, p. 122) that height is allowed, excluding parking floor up to 6.0 m, subject to approval of the Chief Fire Officer or Director of Fire Services where required:
| Authority or area (as printed) | Permissible height | Regulation, page |
|---|---|---|
| Pune, Pimpri-Chinchwad, Nagpur, Nashik, Municipal Corporations in MMR and Metropolitan Authorities area and Area Development Authorities, Special Planning Authorities, CIDCO as Planning Authority by virtue of NTDA within these areas | As per approval from Fire Department | Reg. 6.10.1, p. 122 |
| Remaining Municipal Corporations area and Area Development Authorities, Special Planning Authorities within these areas | 70 m | Reg. 6.10.1, p. 122 |
| All Municipal Councils, Nagar Panchayats, Non-Municipal Council D.P. and Regional Plan areas | 50 m | Reg. 6.10.1, p. 122 |
Practical tip: the table does not name each authority. Ask the planning authority which row it applies to your land.
08Parking, loading and unloading
The regulation says:
- Industrial (Table No. 8-B, p. 150): for every 300 sq. m carpet area or fraction, 2 cars and 9 scooters in a congested area, and 3 cars and 9 scooters in a non-congested area.
- Storage (any type) (same table): for every 300 sq. m carpet area or fraction, 0 cars and 4 scooters congested, and 1 car and 3 scooters non-congested.
- The total is then multiplied by the factor in Table No. 8-C (p. 152) for the authority or area, for example 1.00 for the Pune, Pimpri-Chinchwad and Thane Municipal Corporation areas and PCNTDA area, 0.7 for a Metropolitan Area Development Authority / Area Development Authority / SPA area, and 0.4 for areas in a Regional Plan.
- Loading and unloading (Reg. 8.1.1(viii)(b), p. 146): for industrial and storage buildings, one space for each 1000 sq. m of floor carpet area or fraction thereof exceeding the first 200 sq. m, each at least 3.75 m x 7.5 m, subject to a maximum of 6 for buildings other than offices.
- Parking may use marginal open spaces only if 3.0 m around the building (6.0 m for a special building) is kept free of parking and loading spaces (Reg. 8.1.1(viii)(d), p. 146).
09Using industrial land for something else
The regulation says (Reg. 4.8.1, pp. 66 to 68) that land in the Industrial Zone may be used for residential or commercial uses on conditions, including a premium of 5% of the land value under the Annual Statement of Rates and amenity space. That is a separate route and is not covered further here.
10Checklist before you design or buy
- 1Confirm UDCPR applies at all: the land must not be in MIDC or another excluded area (Reg. 1.1(i), p. 1).
- 2Get the zone in writing: Industrial Zone (Reg. 4.8) or Agricultural Zone (Reg. 4.11(xviii)). The FSI differs.
- 3Measure the existing road width. Table 6-H needs 9 m or 12 m; Agricultural Zone uses need 6.0 m for a non-special building.
- 4Check the plot is at least 300 sq. m and 10 m wide (Table 3D, p. 53).
- 5Work out whether the building is a special building (500 sq. m on any floor, or over 24 m) and pick the Table 6-H row.
- 6Plot the 23.0 m buffer if residential or habitable use adjoins, unless the use is wholly non-polluting.
- 7Price the premium for FSI above the basic figure, and ancillary area FSI if needed.
- 8Ask the authority which height row (Reg. 6.10.1) and parking factor (Table 8-C) it applies.
- 9Lay out parking and loading bays with the 3.0 m or 6.0 m clear zone around the building.
- 10Have your registered architect check every figure against the current text and any later amendment before you file.